RAIS X-Basic Manual do Utilizador Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 19
English RAIS - manual for RAIS 500
20
PRELEMINARY
PRELEMINARY
Mounting distance - 2G / 3G
brick:
If not generating enough convection, there may be damage to the brick walls.
To guide the hot air out of the
gratings, we recommends to
install a non-flammable plate
just above the holes.
It is recommended to knock out the 3
areas - prepared for heat transfer - out.
Distance to furniture
min. 900 mm
Recommended min convection
area below the stove : 500 cm²
(may be distributed)
Recommended min convection
area above the stove : 800 cm²
(may be distributed)
Distance to combustible
material min. 200 mm
Distance to
combustible
material
min. 200 mm
Min. 300 mm
Distance to combustible
material min. 250 mm
Distance
min. 400 mm
Clearance
min. 800 mm
Min. 100 mm
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 35 36